Technical Note / Shielding Design
There is a 15cm long seam with a width of only 0.2mm on the shielding cover of a device. The radiation of the whole machine severely exceeds the standard around 1GHz, and the reading of the copper foil thickness of the shielding cover hardly changes after increasing from 0.1mm to 0.3mm. The reason lies in this slit itself: the half wavelength of free space corresponding to 1GHz is exactly 15cm, and this narrow slit has become a half wave resonant slot antenna electrically. It is not a 'leaking hole', but a 'working radiator'. Thickening the wall surface is basically ineffective for a seam that is already close to resonance - what needs to be changed is the electrical length of the seam and the impedance of the overlap path.
This is also the true value of conductive adhesive copper foil tape: its function is to "sew" the gaps back together and change the grounding path from "connected" to "low impedance". Under the wrong pasting method, it only turns a 15cm seam into two 7.5cm seams, or simply into a new radiating antenna.
The radiation efficiency of the gap is determined by itsMaximum sizeDeciding, not determined by width. When the maximum length of a slit approaches half a wavelength, it will radiate efficiently like a dipole; The seam width only affects the coupling strength and equivalent impedance. This explains a long-standing experience in engineering: by controlling the maximum unsupported gap below λ/20, which is the highest frequency of concern, leakage can usually be suppressed to a level that does not constitute a problem.
Pushing back the product structure according to this table will lead to an less intuitive conclusion: when making 2.4GHz products, the 5cm seam on the shielding cover is already a resonant level defect; When making 800MHz products, the same seam is just a common leak. The same structure, switching to a different operating frequency band, leads to completely opposite conclusions - therefore, gap control must be inferred from the highest frequency of concern (including harmonics), rather than judged based on whether it appears strict or not.
Another easily overlooked point is wall thickness. When the frequency is much lower than the cutoff frequency of the gap, the larger the ratio of the depth to width of the gap, the more obvious the attenuation, and thickening the wall surface is indeed useful; But once the gap length approaches half wave resonance, it becomes a radiator, and the improvement brought by wall thickness quickly saturates. This is the physical reason behind the 'ineffective thickening'.
Look at resistance at low frequencies and inductance at high frequencies. A long and narrow overlap strip may have a DC resistance of only a few milliohms, but at frequencies above several hundred megahertz, its equivalent series inductance is sufficient to make the grounding "suspended". The focus in engineering is on the overlap pointsspacingandOverlapping areaThese two things, not 'whether they are connected or not'.
The empirical aperture of spacing is consistent with the gap: the spacing between overlapping points or vias should be controlled within λ/20 of the highest frequency of interest in order to maintain a low impedance equipotential surface throughout the entire frequency band. The overlap area determines the contact resistance and long-term stability. In practical design, the overlap width is often in the range of 5-10mm. The "point contact" pasting method, which is narrower than this, will rapidly deteriorate after temperature cycling and vibration.
Remember one sentenceCut a long seam into two sections from the middle, which may reduce leakage; Cut each of the two sections into four sections, and the returns will decrease - the truly effective way is to make the electrical length of each section fall out of the resonance zone.
The treatment of corners also affects the results. When turning at a right angle, the tape is stretched on the outside of the bend, wrinkled on the inside, uneven thickness of the adhesive layer, and partial detachment. This is often the starting point of leakage. The common practice is to divide the long strip into sections at the corners and stack them at a 45 ° angle to ensure that each section remains approximately flat.
Adhesive tape is a thin film with almost no compressive resilience. It has no elastic reserve in the thickness direction and cannot absorb assembly tolerances, surface profile differences, and thermal expansion displacement. When the seam width exceeds about 1mm, or there are obvious non parallel structural surfaces on both sides, or there is a need for dynamic sealing with repeated opening and closing, the correct approach is to first use conductive pads (conductive cloth, conductive silicone, conductive foam) to fill the seam and provide compression rebound. Adhesive tape is only used as the outer edge sealing and fixing method.
The other boundary is the low-frequency magnetic field. The magnetic permeability of copper is equal to 1, and it has almost no shielding ability against magnetic fields below several hundred kilohertz. Even the thickest copper foil tape is only a "layer of non-magnetic metal". This type of problem requires high magnetic permeability materials such as Permalloy, nanocrystalline tapes, or flexible soft magnetic wave plates, which have completely different roles from copper foil tapes.
There is also a type of easily stepped pit: using tape as a structural connection or current carrying conductor. The contact area and long-term current carrying capacity of pressure-sensitive conductive adhesive are limited. Metal fasteners should be used at positions such as high current circuits, battery terminals, and grounding bolts, and the tape should only be used for signal level overlap.
The shielding cover itself does not generate common mode current, it is its grounding path that "selects" how the current flows. If the cover only has one grounding point at the far end, common mode current will flow along the cover, and the cover itself becomes the antenna; If the contact points are evenly distributed and close enough, the current is bypassed to the ground level nearby, and the enclosure truly becomes a barrier.
Therefore, in the design phase, three questions need to be answered simultaneously: whether the reference ground plane is complete (whether it has been slotted or cut by wiring), whether the overlap points cover every edge of the cover, and whether the screws and tape form multi-point parallel connections. A common mistake is to use a long piece of tape to "ground" the entire cover by pulling it diagonally from one corner - it provides a high inductance path that is almost equivalent to an open circuit at high frequencies.
Don't just look at a single reading of the radiation emitted by the entire machine. Near field scanning can directly see the leakage location: move the probe along the seam of the cover, and the hotspots will be concentrated in the non overlapping gap segments and corners; Scan again after making changes to see if the hotspot has been cut into several small segments and overall lowered. The whole machine radiation test is used to confirm the margin, and the combination of the two can avoid adding materials based on intuition.
Overlapping impedance can be measured separately: the tape is attached to a sample of the same material according to the actual process, read with a milliohmmeter or impedance analyzer at a specified frequency, and then retested after temperature cycling and wet heat. This type of data is more predictive of mass production performance and easier to write into incoming inspection specifications than single point values on material specifications.
Design self inspection checklistWhat is the highest frequency of concern (including harmonics)? Is the longest unsupported gap less than λ/20 of this frequency? Is the spacing between overlapping points also met? Is the corner transitioning in sections? Is there a pad installed in areas where the seam width exceeds 1mm? Has the cover formed a multi-point parallel low impedance path?
Shielding is never about 'wrapping things up', but about turning every non-existent current path into low impedance. The reason why copper foil tape is irreplaceable is that it is the only material that can fill this path with die-cutting accuracy in a few millimeters of space - provided that it is designed as part of a circuit rather than used as adhesive tape.
For more technical information on conductive shielding materials, flexible soft magnetic absorbing materials, and precious metal pastes, please visitwww.avanzado.cn.
Contact
Company:Xianjin Yuan (Shenzhen) Technology Co., Ltd.
Address: 8/F, Zhongxing Building, Shajing Xinsha Road, Bao'an District, Shenzhen, Guangdong, China
Tel: 0755-22277778 13826586185
Email: Email: duanlian@xianjinyuan.cn
Advanced Institute (Shenzhen) Technology Co., Ltd, © two thousand and twenty-onewww.xianjinyuan.cn. All Rights Reserved.Guangdong ICP No. 2021051947 sitemap