Our main products include flexible substrate coating, shielding materials, absorbing materials, precious metal slurries, and more!

banner
Current:Home >Company news >Frontier News >Magnetic loss absorbing materials: Where does the loss come from and why does high frequency rely on resonance
先进院(深圳)科技有限公司

Hotline:0755-22277778 Tel:0755-22277778 
Mobile:13826586185(Mr.Duan)
Fax:0755-22277776
E-mail:duanlian@xianjinyuan.cn

Frontier News

Magnetic loss absorbing materials: Where does the loss come from and why does high frequency rely on resonance

Time:2026-11-23Number:12

Technical Note  /  Loss Mechanisms

Two types of absorbing materials labeled as "magnetic loss type", one performs well at 500MHz and significantly attenuates to 3GHz; The other one is exactly the opposite, with low frequencies being almost useless and high frequencies being effective. The parameter table all states' magnetic loss', but the difference lies in the source of the loss:Low frequencies rely on hysteresis and eddy currents, while high frequencies rely almost entirely on resonance and relaxation.The frequency dependence of the three paths is different, and as long as one of them is arranged properly, the material will leave gaps in other frequency bands.

Only by understanding this matter can we understand why a μ "curve rises at one frequency and falls at another frequency.

01Loss decomposition: three sources, three frequency dependencies

The total loss of magnetic materials is often divided into three components: hysteresis loss, eddy current loss, and residual loss (the latter mainly includes resonance and relaxation). The frequency dependence of the three is significantly different, which determines the frequency bands in which they can each 'work'.

mechanism Frequency dependence Dominant frequency band Role in absorbing waves
Hysteresis loss Approximately proportional to frequency and related to coercivity Low frequency, strong field Soft magnetic materials are usually intentionally made small, which is not conducive to low loss applications
eddy current loss As the frequency squared increases, it is proportional to the square of the particle size and inversely proportional to the resistivity Mid low frequency, quickly raise the head when the size is large At high frequencies, it is more like "shielding" rather than "absorption" and needs to be suppressed
Remaining loss Peak appears near the resonance frequency High frequency (MHz to GHz) The main mechanism of absorption determines the peak position of μ "

The result of the superposition of the three is the curve you see on the frequency response curve: the low frequency band is gentle, the eddy current slightly rises when it begins to enter, and it rises sharply when approaching resonance, and quickly falls back after the peak. The so-called 'high-frequency failure of this material' is essentially due to the resonance peak having passed and the eddy currents being suppressed, leaving insufficient available losses to absorb energy.

02Eddy current: a good helper for low frequencies and a disruptor for high frequencies

Eddy current losses arise from the induced circulation of alternating magnetic fields within particles. It can indeed contribute to losses at low frequencies, but at high frequencies it brings two troubles: first, the losses are too concentrated on the surface of the particles, making the material more like a "lossy conductor" and enhancing surface reflection; The second is that eddy currents themselves weaken the magnetic flux entering the interior of the material, making deeper layers of the material 'unusable'.

The suppression method has only one direction: to make the particle size smaller than the skin depth of the frequency band, and to insulate each particle from each other. This is precisely why the absorption plate must be coated with flattened resin - flattening compresses the particle thickness to the micrometer level, and coating cuts off the electrical conductivity between particles. If any process encounters a problem, the high-frequency characteristics will immediately degrade.

Remember one sentenceHigh frequency absorption is not about 'the greater the loss, the better', but about 'turning off eddy currents and allowing resonance to come up'.

03Resonance: The only reliable source of loss in the GHz band

After entering the GHz band, hysteresis can already be ignored, and eddy currents are deliberately suppressed. What really works is the resonance and relaxation caused by the magnetization not keeping up in the alternating field. The resonance frequency is determined by the anisotropic field of the material: the stronger the anisotropy, the higher the resonance frequency.

There are two ways to increase the resonance frequency in engineering. Firstly, at the compositional level, choose alloy systems with higher saturation magnetization and stronger anisotropy; The second aspect is the shape aspect, where particles are made into flat pieces and shape anisotropy is used to provide additional anisotropic fields. The latter has lower cost and more direct effect, making it the mainstream route for GHz absorbing wave plates.

The other side of resonance is narrowband. The resonance peak is naturally sharp and rapidly decays outside the peak; To cover a wider frequency range, one can only rely on mixing powders with different resonance frequencies, multi-layer stacking, or using relaxation mechanisms to "widen" the peaks. This is also why broadband products often require multiple powder formulations instead of a single formula.

04Division of labor among three types of loss materials

type Source of Loss Advantages and Limitations
Magnetic loss type μ″, Resonance and relaxation Sensitive to near-field magnetic fields, non-conductive, and thin; Limited bandwidth outside the peak
Dielectric loss type ε″, Polarization relaxation High frequency availability and flexible formula; Not sensitive to magnetic field components
Conductive loss type Conductivity loss Thin and low-cost; Easy to reflect, there is a risk of short circuit near the circuit

The object of near-field suppression is usually the magnetic field component, which is the natural advantage of magnetic loss type: it couples directly with magnetic flux through μ ", does not rely on conductivity, and does not require grounding. In far-field or high-frequency microwave darkroom scenarios, dielectric and structural solutions also have their own applications; Although conductive loss type is cheap, there is always a risk of short circuit and reflection when approaching the wiring and chip.

05The correspondence between design methods and objectives

Design methods Loss of suppression Expectations increase
Flatten to micrometer thickness eddy current The resonance frequency shifts upward, and the high-frequency μ ″ increases
Insulation coating one by one Eddy current and interparticle conductivity Reduce ε and reflection, while maintaining non conductivity
Magnetic field orientation arrangement Local eddy currents caused by disorderly stacking Improve the effective magnetic permeability within the plane
Multi formula mixing/layering Narrowband limitation of single resonance Expand bandwidth to form a bimodal or platform
Improve resistivity and filling consistency Dielectric loss and leakage Improve reliability and batch consistency

06What are the three quantities to consider when reading data

The degree of magnetic loss can be measured by the tangent of the loss angle:tanδm= μ″/μ′It answers' How much magnetic energy does this material convert into heat 'instead of' Is its magnetic permeability high? '. A material with a high μ 'but low tan δ is an excellent magnetic circuit material, but a poor absorbing material - this is the boundary between the magnetic separator and the absorbing plate.

The second quantity is the frequency and peak height corresponding to the μ "peak, which determines whether the material can cover your noise frequency points. The third quantity is the actual proportion of power loss (calculated using the S parameter), which distinguishes reflection from absorption and avoids misinterpreting "strong reflection" as "good absorption".

The technical content of magnetic loss absorbing materials lies in arranging losses in the right frequency band: reducing eddy currents and hysteresis at low frequencies, promoting resonance at high frequencies, and widening peaks through mixing. Understanding the trade-off between these three sources, a frequency response curve is no longer a set of numbers, but an instruction manual on how materials work internally.

For more technical information on magnetic absorbing materials, ferrite materials, and conductive shielding materials, please visitwww.avanzado.cn.

Contact

Contact Us

Company:Xianjin Yuan (Shenzhen) Technology Co., Ltd.

Address: 8/F, Zhongxing Building, Shajing Xinsha Road, Bao'an District, Shenzhen, Guangdong, China

Tel: 0755-22277778   13826586185

Email: duanlian@shturl.cc /evnx

Hotline
0755-22277778
13826586185(Mr.Duan)
Wechat QRcode Wechat QRcode