When a 13.56 MHz NFC tag is stuck to a metal surface and cannot read the card, engineers' first reaction is usually to stick a magnetic sheet. The high magnetic permeability of the sheet material "pulls away" the magnetic field lines from the metal surface, weakens the eddy currents, and allows the tag antenna to regain an effective magnetic field, restoring the reading distance. This logic holds true in most cases, which is why magnetic sheets are called "anti metal sheets" or "magnetic separators".
But this logic has only been partially explained: while suppressing metal eddy currents, magnetic sheets also enter the near-field of the tag antenna. It is not just a "shielding layer in front of metal", it is a high permeability magnetic material that changes the magnetic flux distribution around the antenna, equivalent to adding a component to the antenna inductance. The patent literature has a direct description of this: when the magnetic sheet is close to the antenna pattern, "the inductance of the antenna increases, and the resonance frequency and Q value shift". In other words, magnetic sheets do two things: one is "good" - suppress metal eddy currents; Another thing that needs to be managed is to raise the antenna inductance and make the resonant frequency deviate from the design value. If only the first thing is considered when selecting, the second thing will be exposed in the form of "low efficiency" or "less than expected reading distance" during the whole machine testing.
μ 'is responsible for' magnetic attraction 'and also for' loading '
The complex magnetic permeability of magnetic sheets includes a real part μ 'and an imaginary part μ' '. In the RFID anti metal scenario, the division of labor between the two is clear.
μ ': The source of anti metal benefits and inductive loading
μ 'represents the energy storage and magnetic conductivity of the material. The higher the μ ', the stronger the sheet's ability to guide magnetic flux, and the more magnetic flux is pulled away from the metal surface, resulting in better eddy current suppression effect. This is the foundation of anti metal function.
But μ 'is also a source of inductive loading. After entering the near-field of the antenna, the high μ 'sheet provides a low magnetic resistance path for the magnetic flux, and the equivalent magnetic permeability around the antenna coil increases, resulting in an increase in the inductance L of the coil. The resonant frequency f=1/(2 π√ LC), as L increases, f decreases. For NFC antennas tuned at 13.56 MHz, an increase in L means that the resonance point is shifted towards lower frequencies.
μ "represents magnetic loss. In the anti metal scenario, μ "is not the parameter we want to have" higher, better "- if the loss of the sheet during the process of guiding the magnetic flux is too high, it will consume the limited magnetic field energy of the tag antenna and reduce the Q value. The NFC magnetic separator pursues a combination of "high μ 'and low μ'", which is different from the logic of the absorption plate pursuing "controllable high μ ''.
The core of the problem lies in the fact that the "metal resistance benefit" and "inductance loading cost" of μ 'are two sides of the same parameter. There is no such thing as a μ 'that only increases resistance to metals without increasing loading effects. The task of selection is to find a balance point between the two where the system is still usable, rather than simply pursuing a higher μ '.
The magnitude of loading effect: why 'μ' is high enough 'does not equal' read distance is far enough '
The severity of the loading effect depends on μ ', thickness, and the distance between the sheet and the antenna.
The higher the μ ', the stronger the loading
At 13.56 MHz, the loading of antenna inductance on a sheet with a resolution of 150 μ 'is significantly higher than that on a sheet with a resolution of 45 μ'. TDK's IFL04 series has a μ 'of approximately 45 and a μ' of approximately 1.3 at 13.56 MHz, with a magnetic layer thickness of 0.05 mm. It is positioned as a low loss sheet material that optimizes the coil Q factor. This μ 'value is not high, but it is the result of a trade-off between' loading cost 'and' metal resistance benefit '. In contrast, the IBQ15 series with a thickness of 0.1-0.18 mm and a magnetic layer of μ'150 is designed for scenarios that require stronger magnetic flux guidance capabilities, but the loading effect is also correspondingly greater.
Increasing thickness will amplify the loading effect
Thicker sheets mean more magnetic material enters the near-field of the antenna, resulting in a greater increase in equivalent magnetic permeability and a more significant increase in L. At the same time, the increase in thickness also raises the magnetic flux capacity of the sheet itself, bringing benefits in suppressing eddy currents. The superposition of the two makes thickness a variable that needs to be weighed together with μ ', rather than an independent parameter of' thicker is better '.
The spacing is an adjustable lever in engineering
The air gap or substrate thickness between the sheet and the antenna can weaken the loading strength of the sheet on the antenna. The "notch" design described in the patent is essentially the artificial creation of a localized low magnetic permeability region, which weakens the loading effect at specific locations, thereby achieving a balance between "metal resistance" and "non detuning".
Ferrite and nanocrystals: two types of μ 'levels, two types of engineering boundaries
In the 13.56 MHz RFID scenario, ferrite and nanocrystals are the two main material routes with different μ 'levels, facing different loading problems and engineering costs.
Ferrite route: medium μ ', low μ', predictability priority
The μ 'of ferrite is usually in the range of 100-250 MHz, with mature technology and relatively controllable loss characteristics. Its loading effect exists, but within the matching tolerance range of most NFC tag antennas, it can be compensated by adjusting the matching capacitance. The engineering boundary of ferrite lies in the Snoek limit: there is a constraint between μ 'and the natural resonance frequency, and the space to further increase μ' is limited. For NFC scenarios that require 'medium μ' and low μ ', ferrite has advantages in cost and predictability.
Nanocrystalline route: high μ 'potential, needs to be realized through magnetic fragmentation technology
The μ 'of nanocrystals can be made higher, and the saturation magnetic induction Bs is also higher, which has physical attraction in scenarios that require stronger magnetic flux guidance ability. However, the resistivity of nanocrystals is extremely low. At 13.56 MHz, if magnetic fragmentation and insulation treatment are not carried out, eddy current loss will become the dominant factor, and the μ "value will be high. The loading effect will become a dual burden of" loading loss ". The effective μ 'of the finished product after magnetic fragmentation will decrease, but the uniformity of distribution and the stability of fragment gaps have become new process variables. The engineering boundary of nanocrystals lies in the fact that their high μ 'potential can only be realized after the high-frequency eddy current is suppressed by the demagnetization process, otherwise the cost of loading effect may exceed the benefits of anti metal.
The choice of route does not depend on whose μ 'is higher, but on the matching tolerance of the target tag antenna and the strictness of the metal environment. A low loss ferrite sheet with a diameter of 45 μ 'can absorb loading effects through matching networks on most NFC tags, achieving stable read distance recovery; A sheet of material with a size of 150 μ 'may push the antenna away from the resonance point without corresponding matching adjustments.
Selection judgment based on "combination resonance"
Firstly, select the magnetic sheet as a "part of the antenna" instead of an independent anti metal accessory
The μ 'of the sheet material will change the inductance of the antenna, and the resonant frequency will shift after being mounted. The selection verification should measure the resonance frequency and reading distance in the combination state of "tag antenna sheet metal substrate", rather than only measuring the magnetic spectrum of the sheet itself or the free space reading distance when "no sheet is attached".
Secondly, the supplier is required to provide paired data of the target frequency point's μ 'and μ' ', as well as the loading amplitude of the sheet on the antenna inductance
μ 'alone cannot predict the risk of detuning, and μ' alone cannot predict the anti metal effect. The μ'45/μ ″ 1.3 combination of TDK IFL04 and the μ'150/μ ″ 3 combination of IBQ15 represent two different "loading loss anti metal" equilibrium points. When selecting, it is necessary to confirm the parameters of the sheet at 13.56 MHz and whether the supplier provides reference data for "resonance offset after surface mount".
Thirdly, reserve compensation space for loading effects during the matching design phase
If the μ 'of the sheet material is high, the antenna matching capacitor needs to be calibrated according to the inductance value after mounting in the design stage, rather than first adjusting it according to the free space before mounting. The idea of "notch" in the patent - using local low magnetic permeability regions to counteract loading - can also be used as a supplementary means of matching tuning, but it needs to be confirmed whether the influence of notch position and width on resonance frequency has been measured.
Fourthly, the trade-off between ferrite and nanocrystals should be based on "matching tolerance" rather than "upper limit of μ '"
If the matching network of the tag antenna has a large adjustable range and the metal environment is not extreme, low loss ferrite sheets are a more predictable starting point; If the metal environment requires stronger magnetic flux guidance and the project has the ability to verify the uniformity and consistency of fragmented magnetic nanocrystals, the high μ 'potential of nanocrystals becomes a reasonable option. Do not assume that 'higher μ' is better ', as higher μ' means stronger loading and requires stronger matching compensation to digest.
Advanced Institute (Shenzhen) Technology Co., LtdThe RFID magnetic sheet product line covers ferrite composite sheets and nanocrystalline composite sheets, providing paired data of μ 'and μ "at 13.56 MHz, as well as resonance frequency offset evaluation in the combination state of" tag antenna sheets ".
The product supports matching the material system and thickness based on the matching tolerance of the tag antenna and the metal substrate conditions, helping engineers find a balance between the benefits of metal resistance and the cost of inductance loading. For more technical information, please visithttp://www.avanzado.cn/.