Technical Note  /  DC Bias Behavior

According to the specification sheet, μ=60 is used to calculate 15 μ H, but when the prototype is installed and tested at full load current, it only has 9 μ H. This is not a miscalculation, nor is there a problem with the magnetic core, but rather the normal state of soft magnetic composite materials:Its magnetic permeability gradually decreases with the magnetic field strength from zero current, and there is almost no "stable platform".This behavior, known as soft saturation, is both favored in power scenarios and the most commonly underestimated variable in design.

To understand it, one must first look at the flattened B-H curve.

01Why is it 'soft' saturation

The slope of the B-H curve of a magnetic core is the magnetic permeability. The curve of traditional ferrite or silicon steel is steep in the low field region and suddenly bends near saturation - the magnetic permeability remains stable for a long time, and then collapses sharply near a certain current. Soft magnetic composite materials disperse the air gap inside the material, which is equivalent to connecting a large number of extremely short air segments in series on the magnetic circuit. The entire curve is flattened from the beginning: the slope is low, the extension is long, and the inflection point is blurred.

This' flattening 'has two direct consequences in engineering. Firstly, achieving the same magnetic flux density requires a greater magnetic field strength, that is, more ampere turns; Secondly, the decrease in magnetic permeability is gradual and there is no sudden failure at any point. The former means that the volume or number of turns needs to increase, while the latter means that the inductance slowly "shrinks" when the current increases, rather than disappearing instantly.

behavior Ferrite Soft magnetic composite materials
initial permeability High (hundreds to thousands) Low (dozens)
Saturation process Steep, quickly loses sensitivity after approaching a certain current Smooth, the magnetic permeability gradually decreases throughout the entire process
High current performance Easy to collapse suddenly, leaving a large margin Gradually shrinking, predictable behavior
Design difficulties Determine which point is considered saturated Calculate inductance based on which level of magnetic permeability

The last line is the design core of soft magnetic composite materials: the magnetic permeability on the specification sheet is the value under zero bias or small signal, but in actual operation, it may only be 60-70% or even half. Calculating inductance with initial values always yields optimistic numbers.

Remember one sentenceThe magnetic permeability of soft magnetic composite materials is not a number, but a curve that varies with current.

02Three step calculation: from geometry to working point

Taking common annular or rectangular magnetic cores as an example, first estimate the zero bias inductance according to the classical magnetic circuit formula:

L = μ 0μ eN 2A e/ l eB ≈ μ 0μ eN I / l e

Take an actual quantity: take Ae=100mm²、le=50mm、μe=If N=10 turns, then the zero bias inductance is approximately on the order of 15 μ H; When the current rises to 10A, the magnetic flux density calculated by the same formula is about 0.15T. This value is much lower than the saturation level of the material, but the magnetic permeability may have dropped to 60% to 80% of the initial value - the actual inductance therefore falls within 9-12 μ H.

This is the crucial step among the three steps:First calculate the magnetic flux density at the working point, then look back at the magnetic permeability under that flux, and finally recalculate the inductance.Most manufacturers provide a percentage curve of μ decreasing with DC bias, which can be used for quick interpolation. If the data is missing, a conservative value of around 70% is usually not too far away, but this is only temporary.

The third step is to verify the temperature rise. The heat generated by losses will cause the temperature of the magnetic core to rise, and both magnetic permeability and losses change with temperature; When the temperature rise is too high, the loss further increases, forming a positive feedback. When designing, the losses, thermal resistance, and allowable temperature rise at rated current should be calculated together, rather than just looking at whether the inductance meets the standard.

03Mutual coupling with ripple

In a switching power supply, the inductance determines the current ripple, which in turn changes the peak current and magnetic flux swing. In materials where magnetic permeability varies with current, these two quantities are mutually constrained: the inductance calculated based on the initial μ is larger, and the actual ripple ratio is expected to be larger; If the ripple is large, the peak current will be high, the magnetic permeability will further decrease, the inductance will be smaller, and the ripple will increase again.

The solution is iterative: first estimate the inductance and ripple based on conservative magnetic permeability, calculate the magnetic flux corresponding to the peak current, check the μ under this magnetic flux, and then update the inductance. Repeat for two or three rounds to converge. In most cases, the numerical changes after two rounds are less than the engineering tolerance.

The performance of this step varies greatly between light and heavy loads: under light load, the magnetic permeability approaches the initial value and the ripple is small; When overloaded, the magnetic permeability decreases and the ripple significantly increases. If only the rated load is verified, the stability of the loop under light load is easily overlooked; On the contrary, only measuring light loads will underestimate the ripple and losses under heavy loads.

04Three common misjudgments

misjudgment Source consequence
Calculate inductance using initial μ The specification sheet only provides single point values Full load inductance and ripple both exceed the standard
Treating 'soft saturation' as' unsaturation ' The curve is gentle and there is no obvious turning point visible Ignore the fact that the magnetic permeability has decreased by half
Verify only on one current level Test point selected at rated load Stability under light load or temperature rise under heavy load missed detection

The soft saturation of soft magnetic composite materials is not a design defect, but a strategy of replacing "sudden failure" with "gradual concession": as the current increases, the inductance gradually decreases, and the system still has room for adjustment, without suddenly losing energy storage capacity at a certain current like ferrite. By understanding and accepting this curve, the design will not be trapped in the prototype stage by 'inexplicably missing a few micro henries'.

For more technical information on soft magnetic composite materials, magnetic materials, and power devices, please visitwww.avanzado.cn.

Contact

Contact us

Company:Xianjin Yuan (Shenzhen) Technology Co., Ltd.

Address: 8/F, Zhongxing Building, Shajing Xinsha Road, Bao'an District, Shenzhen, Guangdong, China

Tel: 0755-22277778   13826586185

Email: duanlian@xianjinyuan.cn

Hotline
0755-22277778
13826586185(Mr.Duan)
Wechat QRcode Wechat QRcode