Our main products include flexible substrate coating, shielding materials, absorbing materials, precious metal slurries, and more!

banner
Current:Home >Company news >Frontier News >50 μ m PI copper plated film: When FPC requires a stronger "skeleton" - the engineering value of thick substrates in bending resistance and high reliability applications
先进院(深圳)科技有限公司

Hotline:0755-22277778 Tel:0755-22277778 
Mobile:13826586185(Mr.Duan)
Fax:0755-22277776
E-mail:duanlian@xianjinyuan.cn

Frontier News

50 μ m PI copper plated film: When FPC requires a stronger "skeleton" - the engineering value of thick substrates in bending resistance and high reliability applications

Time:2026-09-09Number:19

1、 When the number of bends of FPC becomes the upper limit of the product's lifespan

50 μ m PI copper plated film · Industrial grade bending resistant FPC substrate

The bending life of FPC directly determines the service life of the entire product in the hinge area of foldable screen phones, dynamic connections in the mechanical arm joints, and the repeated opening and closing mechanism in the car cabin. The design constraints faced by engineers are: the equipment requires the FPC to be "thin enough" to fit into narrow spaces, while also requiring the FPC to be "strong enough" to withstand repeated bending without failure.

In dynamic bending, the failure mode of FPC is usually copper layer fatigue fracture. A thicker PI substrate provides stronger mechanical support, allowing bending strain to be borne more by the substrate rather than concentrated in the copper layer. Industry data clearly states that for FPC customers considering resistance to bending and compression, it is recommended that PI choose a thickness of 50 μ m or 38 μ m. 50 μ m is positioned as the standard thickness for industrial grade bending resistance. The 50 μ m PI copper plated film is a product formed by endowing a thick PI substrate with conductive function through vacuum sputtering copper plating process based on this engineering understanding.

Core Positioning:The 50 μ m PI copper plated film is positioned for industrial grade bending applications, exchanging thick substrates for higher bending life and reliability.

2、 Engineering logic of 50 μ m thick substrate

In the thickness spectrum of FPC substrates, different thicknesses correspond to different engineering positions. 12.5 μ m oriented towards high-density interconnect (HDI) products, pursuing ultimate thinness and lightness; 25 μ m is the standard specification in the field of consumer electronics; 50 μ m is positioned for industrial grade bending resistant applications.

Higher fatigue life

Dynamic bending compromise, thick substrate provides stronger mechanical support, and more strain is borne by the substrate, reducing the risk of copper layer fatigue fracture. In terms of substrate, 25 μ m PI is suitable for light, thin, and small spaces, while 50 μ m PI substrate has characteristics such as pressure resistance, bending resistance, and good rigidity.

Better dimensional stability

Large heat capacity and high rigidity, with small dimensional changes and higher accuracy in high-temperature processes such as welding and bonding. Fine lines with a spacing of 50 μ m (25 μ m line width/line spacing) can be achieved on a 50 μ m thick PI film.

Stronger tear resistance

In connectors that are frequently plugged or subjected to force, 50 μ m substrates effectively resist tearing and delamination, while traditional 25 μ m connectors are prone to tearing.

3、 Non adhesive 2L-FCCL: structural advantage of eliminating adhesive layer

The 50 μ m PI copper plated film belongs to the 2-Layer Flexible Copper Clad Coating (FCCL) without adhesive, which is directly composite of PI substrate and sputtered copper layer, without an adhesive layer in the middle. Compared with traditional three-layer FCCL with adhesive (3L-FCCL), the non adhesive structure brings multiple engineering advantages:

  • Thinner overall thickness:By eliminating the adhesive layer, the overall thickness of the material is significantly reduced, which can save more space under the same stacking structure.
  • Higher heat resistance:The adhesive layer is the temperature bottleneck of traditional FCCL - the adhesive layer may age, carbonize, or delaminate at high temperatures. The non adhesive structure eliminates this hidden danger.
  • Better dimensional stability:The thermal expansion coefficient of the adhesive layer does not match that of PI and copper, which can easily lead to warping and deformation in high-temperature processes. The CTE of the adhesive free structure is closer to copper foil and has better dimensional stability.
  • Higher peel strength:The copper layer of non adhesive FCCL is directly bonded to the PI substrate, and the bonding strength is better than that of adhesive products. The peel strength can reach a good level of 7-9 N/cm.

4、 Vacuum Sputtering Copper Plating: Constructing Precision Conductive Layer on 50 μ m Substrate

The copper layer of 50 μ m PI copper plated film was prepared using roll to roll (R2R) vacuum magnetron sputtering process, and a copper conductive layer was deposited on high-purity oxygen free copper as the target material in a vacuum environment. This process endows the surface of PI film with metallic conductive and thermal properties, while inheriting the original high temperature resistance, good insulation, and high mechanical strength of PI film. Through the composite process of sputtering and electroplating, the thickness of the copper layer can reach 2-9 μ m.

Higher temperature tolerance

Large heat capacity, less prone to shrinkage and warping, and good process stability.

Tension control is more tolerant

High mechanical strength, not easily stretched or deformed, wide process window, and high yield.

Better uniformity of coating

The substrate is flat and stable, runs smoothly, and has excellent deposition uniformity.

Advanced Institute of Technology:By adopting a roll to roll continuous production process, efficient, continuous, and uniform deposition of metal layers can be achieved on various flexible film surfaces such as PI, PET, PEN, etc., with substrate thickness covering 7.5-125 μ m.

5、 Copper layer thickness: Performance range from 5 μ m to 18 μ m

Based on a 50 μ m PI substrate, copper plated film products with different copper layer thicknesses can be prepared by precise control of process parameters. The thickness of the copper layer varies from 5 μ m to 18 μ m, and different thicknesses correspond to different performance priorities. Copper layer thickness of 2-9 μ m is suitable for the production of thin circuit (Pitch<30 μ m) products. >

Product Type Copper layer thickness Key Features Typical Applications
50 5PI copper plated film ~5 μm Moderate copper layer, good flexibility and balanced conductivity Flexible FPC signal line, conventional EMI shielding
50 10PI copper plated film ~10 μm Thick copper layer, low resistance, good current carrying capacity High current FPC circuits, automotive electronic connectors
50 12PI copper plated film ~12 μm Thick copper layer, extremely low resistance, high current carrying capacity Power line, power FPC, industrial control
50 18PI copper plated film ~18 μm Ultra thick copper layer, extremely low square resistance, high reliability High power transmission, battery connection, aerospace

Note: The thickness of the copper layer is the nominal reference value, and the specific performance is subject to the actual product specifications. The thickness of the copper layer can be customized, usually ranging from 2-18 μ m.

Selection suggestion:Based on the comprehensive balance of current carrying capacity, bending life, and etching accuracy. The thinner the copper layer, the better the flexibility and the higher the precision of the thin circuit; The thicker the copper layer, the stronger the conductivity and higher the current carrying capacity.


6、 Key performance: 50 μ m specification technical confidence

heat resistance

Long term -269 ° C~260 ° C, short-term>400 ° C, thick substrate with large heat capacity, and more stable high-temperature process. The thermal stability of advanced institute technology products reaches 260 ° C.

mechanical properties

Tensile strength ≥ 170MPa, complete conductive path after 100000 bending tests, and no cracks after ten bends.

peel strength

Non adhesive 2L-FCCL, coating adhesion grade 5B (ASTM D3359 highest grade), peel strength>8.0N/cm.

Size and flexibility

Excellent dimensional stability, highly flexible, excellent uniformity of copper layer, and can achieve fine wiring with a spacing of 50 μ m on a 50 μ m PI.

7、 Application scenarios: From durable FPC to high reliability electronics

FPC resistant to bending and compression damage

Core applications. Folding screen hinge, sliding cover cable, and dynamic connection of mechanical arm joints, with a recommended thickness of 50 μ m or 38 μ m in the industry.

Automotive Electronics

Tg ≥ 280 ° C, certified by AEC-Q200 automotive standards, suitable for high temperature, vibration resistance, and high reliability scenarios.

High current and power FPC

Thick copper (10-18 μ m) combined with 50 μ m substrate, suitable for BMS and power module connections, replacing traditional wire harnesses.

Industrial/Medical and Aerospace

High reliability industrial control and medical equipment; PI is resistant to high temperatures (250-280 ° C), radiation, and chemical corrosion, and is widely used in the aerospace industry.

8、 Selection considerations: from copper layer thickness to application scenarios

Copper layer thickness and current carrying capacity

50 5PI is suitable for signals; 50 10/12PI is suitable for power supply; 50 18PI is suitable for high power.

Bending life

The 50 μ m substrate itself has excellent bending resistance and better fatigue resistance than the thinner copper layer (5 μ m).

Etching accuracy

Thin copper layer (5 μ m) is suitable for high-precision thin circuits; Thick copper layer (18 μ m) has a long etching time and is suitable for wide linewidth power lines.

Working environment and processing

Automotive electronics require AEC-Q200 certification; Advanced Institute Technology products have passed the vehicle specification certification. Support customization of substrate 5-125 μ m and copper layer 0.5-50 μ m.

9、 Conclusion

The essence of 50 μ m PI copper plated film is an engineering trade-off between the flexibility and reliability of FPC. It is not pursuing 'extreme thinness', but pursuing' sufficient strength '- exchanging thicker PI substrates for higher flexural life, better dimensional stability, and stronger current carrying capacity. In engineering scenarios that require FPC to withstand repeated bending, high currents, or harsh environments, 50 μ m provides reliability guarantees that are difficult to replace with 12.5 μ m and 25 μ m.

For FPC design engineers, understanding the engineering logic behind the thickness of 50 μ m - requiring thicker substrates for resistance to bending and compression, thicker copper layers for high currents, and stronger "skeletons" for high reliability - is more valuable than simply comparing thickness values. On this thickness platform, customizing products with different properties by adjusting the thickness of the copper layer (from 5 μ m to 18 μ m) is a key step in transforming "thick substrates" into specific engineering solutions.

View product series

www.avanzado.cn

Contact Information                     Company: Xianjin Yuan (Shenzhen) Technology Co., Ltd.                     Address: 8/F, Zhongxing Building, Shajing Xinsha Road, Bao'an District, Shenzhen, Guangdong, China                     Tel: 0755-22277778 13826586185                     Email: duanlian@xianjinyuan.cn

&copy; 2026 Xianjin Yuan · 50 μ m PI Copper Plating Film Technology Reference

Hotline
0755-22277778
13826586185(Mr.Duan)
Wechat QRcode Wechat QRcode