Implantable cortical microelectrode with flexible neural interface
In the 1980s, the invention of the Utah Array and Michigan Array allowed neuroscientists to record the firing activity of hundreds of neurons simultaneously for the first time. These silicon-based microelectrode arrays perform well in acute experiments with high signal-to-noise ratio and precise spatial resolution.
But when electrodes need to be implanted for a long time, a problem gradually emerges: the signal continues to decay for weeks to months and eventually disappears completely.
Researchers have found that the root of the problem lies not in the electronic design of the electrodes, but in the "mechanical war" between the electrodes and the brain. The Young's modulus of silicon is about 190GPa, while the modulus of brain tissue is only 1-10kPa. This mechanical mismatch of over six orders of magnitude causes micro motion damage to every tiny brain movement - breathing, heartbeat, head rotation - at the electrode tissue interface. Injury triggers an immune response, and astrocytes and microglia form a glial scar wrap around the electrode, physically isolating the electrode from neurons. After 13 months of implantation of traditional stainless steel wire electrodes, the thickness of the coating exceeded 451 μ m. Neurons gradually degrade and die, and signals disappear accordingly.
Core proposition:The core engineering proposition of implantable cortical microelectrodes is clear: how to make an "electron probe" learn to "coexist peacefully" with the soft brain while maintaining high-density neural recording ability?
Implantable cortical microelectrode array is an invasive neural interface device that directly penetrates the cerebral cortex and implants into neural tissue, capable of recording action potentials (spikes) of single or multiple neurons. According to the different electrode structures, they are mainly divided into the following types:
The rise of flexible neural electrodes stems from a simple physical insight: in order for implants to coexist with the brain for a long time, their mechanical properties need to be matched.
The Young's modulus of flexible materials such as PI and Parylene-C is much lower than that of silicon and closer to brain tissue. The stiffness of LCP based electrodes is only 1/11 of that of traditional electrodes.
The 5 μ m Parylene microneedle electrode demonstrated recording ability after implantation for one day and can last for over a year.
After 13 months of implantation, the encapsulation layer of NeuroWorm is less than 23 μ m, while that of traditional stainless steel electrodes is greater than 451 μ m.
To achieve flexible cortical microelectrodes, substrate selection is the first hurdle. The current mainstream flexible substrates include:
The most widely used, with excellent thermal stability, impermeability, low dielectric constant, and advanced technology substrates that can be as thin as 5 μ m.
Excellent biocompatibility and conformal coating ability, achieving minimally invasive in vivo recording with 5 μ m microneedles.
Water absorption rate<0.1%, 25 times higher electrode density, stiffness only 1% of traditional electrodes
Excellent biocompatibility and chemical stability, microstructure films can be oriented and arranged in an orderly manner.
Advanced Institute of Technology:The coating process is suitable for substrates such as PI, Parylene, LCP, PEEK, as well as elastic materials such as PET, FEP, PPS, PDMS, TPU, etc.
Flexible substrates provide a "skeleton" for mechanical adaptation, but the collection of neural signals ultimately depends on the conductive layer - the coating process is the key link in transforming flexible polymers from "insulating films" to "functional electrodes".
Advanced Institute Technology's ultra-thin gold micro electrode array exhibits excellent electrochemical performance of 0.73 Ω· cm ².
The coating must comply with ISO 10993 and GB/T 16886 biocompatibility standards.
Degradation analysis of platinum electrodes and SIROF electrodes in the human body for up to 956-2130 days.
High density arrays require micron/nanometer level patterning accuracy and 5B level adhesion.
Chemical inertness, low impedance (0.85k Ω @ 1kHz, reduced by 81% after gold nanosheet modification), strong processing adaptability, suitable for high-density recording electrodes.
Electrocatalytic activity and long-term stability make SIROF electrodes twice as likely to record as platinum electrodes.
| Coating scheme | Core advantages | Typical impedance | Applicable scenarios |
|---|---|---|---|
| Gold plating (Au) | Chemical inertness, low impedance, strong processing adaptability | 0.85kΩ@1kHz | High density recording electrode, flexible probe |
| Platinum plating (Pt) | Electrocatalytic activity, long-term stability | Depending on the process | Electrode with electrical stimulation function, long-term implantation |
| Pt/PEDOT: PSS composite | Extremely low impedance, high charge injection capability | Below pure platinum electrode | High performance recording stimulation dual-mode electrode |
Advanced Institute (Shenzhen) Technology Co., Ltd. was established in 2016, headquartered in Bao'an District, Shenzhen. It has an independently registered trademark "Research Platinum" and has dual production bases in Shenzhen and Dongguan. It has passed ISO9001 quality management system certification. The company focuses on metal plating technology and has developed three types of flexible substrate coating solutions: silver plating, gold plating, and platinum plating.
At the core coating process level, Advanced Institute Technology adopts composite physical vapor deposition (PVD) processes such as magnetron sputtering and vacuum evaporation, which can deposit metal coatings on various flexible polymer film substrates such as PI, PET, FEP, LCP, PEEK, PPS, etc. It can cover a full range of metals including gold, silver, copper, aluminum, tin, nickel, titanium, platinum, etc. The substrate width can reach 350mm, and the ultimate vacuum degree can reach 1 × 10 ⁻⁴ Pa.
Plasma pretreatment ion beam assisted deposition, gold coating and PI form atomic level bonding, with 5B level adhesion.
Pulse electroplating technology reduces porosity to<0.5>
Cyanide free gold plating technology reduces environmental pollution and improves operational safety.
September 2025:Published by the team of Shenzhen Advanced Technology Research Institute of the Chinese Academy of Sciences in NatureNeuroWormAchievement - A flexible and drivable nerve fiber electrode with a diameter of only 196 μ m can "travel" in the skull and actively change monitoring targets, proposing for the first time a new paradigm of brain computer interface "dynamic electrode".
On May 18, 2026:Our country's first128 channel fully implantable brain computer interface systemThe multi center clinical trial has officially started, with Beijing Temple of Heaven Hospital as the leading unit and 11 medical institutions joining. The flexible electrode adopts ultra-thin biocompatible materials, significantly reducing the immune response after implantation and accurately capturing high spatiotemporal resolution single neuron action potentials.
Market data:The global flexible neural electrode market is expected to reach a scale of 480 million US dollars by 2025, a year-on-year increase of 34%; The flexible brain electrode market has become a dual focus of capital and research with a scale of 4.27 billion US dollars and a growth rate of 37.2%.
The essence of implantable cortical microelectrodes is to find an engineering balance between "high-density neural recording" and "long-term biocompatibility". Traditional silicon-based electrodes have traded rigidity for high signal-to-noise ratio and mature MEMS manufacturing processes, but have been losing ground in the face of the softness and dynamics of the brain. Flexible polymer based electrodes take mechanical adaptation as a breakthrough point, using materials such as PI, Parylene, LCP, PEEK to match the softness of brain tissue, and constructing low impedance and high stability conductive interfaces using precision gold/platinum plating processes.
Understanding the material logic of flexibility - why PI instead of silicon, why gold instead of copper, why 5B level adhesion is crucial to the survival of electrodes - is the key to upgrading cortical microelectrodes from "laboratory devices" to "clinical tools". In this paradigm shift from rigidity to flexibility, precision coating technology has always been the core variable determining the upper limit of electrode performance.