Our main products include flexible substrate coating, shielding materials, absorbing materials, precious metal slurries, and more!

banner
Current:Home >Company news >Frontier News >Double conductive copper foil tape: When the adhesive surface also becomes a conductor - how to rewrite the engineering rules of EMI shielding and grounding for Z-axis conduction
先进院(深圳)科技有限公司

Hotline:0755-22277778 Tel:0755-22277778 
Mobile:13826586185(Mr.Duan)
Fax:0755-22277776
E-mail:duanlian@xianjinyuan.cn

Frontier News

Double conductive copper foil tape: When the adhesive surface also becomes a conductor - how to rewrite the engineering rules of EMI shielding and grounding for Z-axis conduction

Time:2026-09-13Number:3

Double conductive copper foil tape: Z-axis conduction scheme that allows current to "pass vertically"

1、 The 'Crossover Dilemma' of an EMC Engineer

At the EMC rectification site of electronic devices, engineers often face a specific engineering problem: there is a gap between the surfaces of two conductors that require electrical connection, how can the current "cross over"?

Stick copper foil tape on the gap - this is the most direct way of thinking. But the problem is that after the tape is attached, the current must pass through the adhesive layer from one side of the conductor to the other side of the conductor, and the adhesive surface must be conductive. The adhesive surface of the single conductive copper foil tape is insulated, and the current can only travel along the copper foil surface and cannot "pass through" the adhesive surface to reach the object being pasted. In scenarios where it is necessary to cross two conductive surfaces and establish a Z-axis grounding path, single conductive copper foil tape is powerless.

A more subtle issue arises in high-frequency circuits. Even if a single conductive tape establishes a grounding path through the copper foil surface, the shielding effectiveness decreases significantly with every slight increase in impedance of the grounding circuit. The longer the path of the current, the smaller the contact area, the higher the circuit impedance, and the worse the discharge effect of high-frequency interference. What engineers need is a conductive path that allows current to "vertically pass through" - this is the engineering reason for the existence of double conductive copper foil tape.

2、 The structure of double conductive copper foil tape: the "three-way conduction" of copper foil conductive pressure-sensitive adhesive

The structure of double conductive copper foil tape seems simple, with only three layers: copper foil layer, conductive pressure-sensitive adhesive layer, and release layer. But it is precisely the collaboration of these three layers that achieves Z-axis conductivity that cannot be achieved by a single conductive tape.

The copper foil layer is a high-purity electrolytic copper foil, with a copper purity of ≥ 99.98% and a thickness typically between 0.018mm and 0.05mm. High purity copper provides a low resistance X-Y direction conductive path - this is the basis for electrical signal shielding. When electromagnetic waves encounter a highly conductive copper layer, most of the energy is reflected and a small portion is consumed in the form of eddy currents.

The conductive pressure-sensitive adhesive layer is the essential difference between dual conductivity and single conductivity. The double conductive tape adopts conductive acrylic pressure-sensitive adhesive, and nickel metal particles are added to the adhesive layer formula. These conductive particles are evenly dispersed in the adhesive layer. When the adhesive layer is adhered between two conductor surfaces, the conductive particles come into contact with each other, forming a vertical conductive path from the adhesive surface to the copper foil. Therefore, the dual conductive copper foil tape has both XY direction (copper foil surface) and Z direction (adhesive surface penetration) conductivity, forming a three-way conductive electrical path. From the appearance, it can be intuitively distinguished that the adhesive surface of the double guide tape contains small particles and is slightly uneven, while the adhesive surface of the single guide tape is flat.

3、 The 'dual identity' of nickel particles: conductive filler and magnetic shielding medium

The role of nickel particles in double conductive tape is not only as conductive fillers. Nickel is a ferromagnetic metal that can guide and absorb magnetic field lines, and has a shielding effect on magnetic signals. This means that the double conductive copper foil tape not only conducts in the Z-axis, but also provides magnetic shielding ability from the nickel particles in its adhesive surface.

This feature enables dual conductive copper foil tape to achieve both electrical and magnetic shielding: copper foil is responsible for electrical signal shielding - relying on the excellent conductivity of copper itself; The nickel in the adhesive surface is responsible for magnetic signal shielding - achieving shielding effect by guiding and absorbing magnetic field lines. The adhesive surface of the single conductive copper foil tape does not contain nickel particles and mainly provides electrical shielding; Double conductive copper foil tape is a necessary choice for scenarios that require simultaneous shielding of electrical and magnetic signals.

4、 Single lead vs double lead: Understanding the selection boundary with one table

The difference between single conductor and double conductor copper foil tape ultimately lies in the difference of "how many paths can the current take". This difference determines that the application boundaries of the two products are completely different.

characteristics Single conductive copper foil tape Double conductive copper foil tape
Copper foil surface conductivity conduct electricity conduct electricity
Adhesive surface conductivity Non-conductive (insulating) Conductive (containing conductive particles such as nickel)
Current path Only copper foil surface (X-Y direction) Copper foil adhesive surface (X-Y-Z three directions)
Appearance of adhesive surface level Containing small particles, slightly uneven
Magnetic shielding mechanism None (the adhesive surface does not contain nickel) Nickel particles on the adhesive surface provide magnetic shielding
typical scenario Insulation surface shielding, single-sided grounding, anti short circuit isolation Crossover conductive surface, double-sided conductive grounding, shielding cover seam

The core application scenarios of dual conductive copper foil tape include: the need for conductive connection between two conductive casings - the dual conductive tape is attached to the gap, the adhesive surface is in contact with both sides of the casing, and the conductive particles form a bridging path to complete the electrical connection; The PCB grounding pad needs to be connected to the metal frame to release static electricity - the adhesive surface of the double conductive tape is directly attached to the pad and the metal frame, and Z-axis conductivity completes grounding; The conductive connection between the cable shielding layer and the metal connector housing; Maintain electrical continuity at the joints between the components of the shielding cover; Provide conductive connections on surfaces that cannot be welded.

5、 Key performance parameters

comprehensiveAdvanced Institute of TechnologyAccording to the official website and industry public information, the key performance indicators of double conductive copper foil tape are as follows:

performance metrics typical value Data source
Copper foil purity ≥99.95%–99.98% Advanced Institute of Technology Product Data
Copper foil surface resistance ≤0.05Ω/inch GB/T30139
Surface resistance of adhesive surface ≤0.09Ω Industry public information
Vertical resistance (Z-axis) <0.03Ω Advanced Institute of Technology Product Data
Shielding Effectiveness ≥80dB Advanced Institute of Technology Product Data
Adhesive force (0.018mm dual guide) 1115N/mm Advanced Institute of Technology Product Data
Adhesive force (0.025mm dual guide) 1120N/mm Advanced Institute of Technology Product Data
Temperature resistance range -10 ° C to 120 ° C (long-term); Used below 100 ° C Advanced Institute of Technology Product Data
copper thickness 0.018mm / 0.025mm / 0.035mm / 0.050mm Customizable as needed
width 5–500mm Customizable slitting

Vertical resistance<0.03 Ω means that the vertical conduction path of current from the adhesive surface to the copper foil has extremely low resistance, which is sufficient to meet the low impedance requirements of the grounding circuit. A shielding effectiveness of ≥ 80dB means that 99.999999% of electromagnetic wave energy is effectively attenuated, which is sufficient to cover the majority of civilian and industrial EMI shielding needs.

6、 A real engineering verification: 3-minute retest, interference value drops by 92% directly

The value of double conductive copper foil tape has been directly verified at the EMC rectification site. A certain electronic laboratory in Nanshan, Shenzhen has experienced faults such as spectrum analyzer reading jumps, frequent disconnection of wireless modules, and three testing devices reporting errors simultaneously. The engineer searched continuously for two hours without success, and finally lifted the bottom plate of the shielding box to find that the original conductive adhesive layer had aged and fallen off, and the electromagnetic leakage at the gaps exceeded the standard. The engineer cut a section of double conductive copper foil tape and compacted it along the seam for 5 seconds. After 3 minutes of retesting, the interference value decreased by 92%.

This case reveals the core value of dual conductive copper foil tape in on-site rectification: it is not the most "advanced" shielding material, but it is one of the most direct, fast, and reliable solutions in gap bridging and grounding repair scenarios. The Z-axis conductivity of the adhesive surface enables the tape to complete electrical connections while being bonded, without the need for additional welding or mechanical fixation.

7、 Selection considerations: from current path to working environment

  • Confirm the current path requirements.This is the core selection criterion. If the application scenario requires current to pass through the adhesive layer (such as bridging two conductive surfaces or using the tape as a grounding path at the same time), double conductive copper foil tape is the correct choice; If only the copper foil surface is needed for conductivity and the adhesive surface is only responsible for bonding, single conductive copper foil tape can meet the requirements.
  • Confirm the requirement for blocking type.In scenarios where both electrical and magnetic signals need to be shielded, double conductive copper foil tape (with nickel particles on the adhesive surface to provide magnetic shielding) should be selected; Select single conductor for scenarios that only require electrical shielding.
  • Pay attention to the vertical resistance and grounding circuit impedance.In high-frequency circuits, the impedance of the grounding circuit directly affects the shielding effectiveness. The vertical resistance of the double conductive copper foil tape is less than 0.03 Ω, ensuring the low impedance characteristics of the Z-axis conduction path.
  • Pay attention to the working temperature range.The long-term use temperature of double conductive copper foil tape is usually below 100 ° C, while the application temperature range of acrylic adhesive is -10 ° C to 80 ° C. In situations where reflow soldering is required, high-temperature resistant models should be selected.
  • Surface treatment cannot be omitted.Before bonding, the surface of the object to be bonded should be cleaned with alcohol or isopropanol to remove oil stains and dust. After bonding, apply uniform pressure with a scraper to ensure that the conductive particles fully contact the surface of the object being bonded.

8、 Conclusion

The value of dual conductive copper foil tape lies not in being "more advanced than single conductive", but in "solving problems that single conductive cannot solve" - in engineering scenarios that require current to penetrate the adhesive layer, achieve double-sided conductivity, and gap bridging, it is an irreplaceable solution. The copper foil surface provides a low resistance X-Y direction conductive path and electrical signal shielding, while the conductive pressure-sensitive adhesive layer achieves Z-axis conduction and provides magnetic signal shielding through nickel conductive particles - the two work together to form a complete electromagnetic shielding and electrical connection function.

Understanding the engineering boundary between "single conductor" and "double conductor" - when current needs to penetrate the adhesive layer and when not - is more valuable than remembering a bunch of parameters.

Contact Us

Company:Xianjin Yuan (Shenzhen) Technology Co., Ltd.

Address:8/F, Zhongxing Building, Shajing Xinsha Road, Bao'an District, Shenzhen, Guangdong, China

Tel:0755-22277778  13826586185

Email:      duanlian@xianjinyuan.cn

Website:      http://www.avanzado.cn/

Related news
Hotline
0755-22277778
13826586185(Mr.Duan)
Wechat QRcode Wechat QRcode